(3||1) teac |
 |
| | Specific Details | Includes: One Barber - Coleman 7HI 1/8 DIN 4-Digit Horizontal Digital Indicator.
C9 | | | Item Tested?: Not Tested Terms of Sale: Guaranteed Not DOA Physical Condition: Excellent | Working Condition: Not Fully Test, but Powers Up | | | | | | Manufacturer's Description | The 7HI/7HK 1/8 DIN horizontal indicators offer outstanding performance in a cost effective package. Designed specifically for equipment manufacturers who need process monitoring and alarm, the 7HI/ 7HK are easy to configure and use. Factory calibrated, they accept thermocouples, 3-wire Platinum RTD, and mV, mA and Vdc inputs, selectable from the front panel and programmable with filtering and sensor break indication. High or low process alarm setpoints can be programmed and password protected. Alarms can be acknowledged automatically, or manually from the keypad. A bright 4-digit LED display and 6 panel beacons provide process variable, alarm status and other important process information to the operator. Both models are NEMA 4X rated.
Both have a peak high/peak low feature that remembers the highest and lowest detected process variable readings. This sequence can be reset and restarted from the front panel.
7HI - The 7HI has up to 3 independent latchable alarm relays (2 SPDT and 1 SPST) programmed for high or low process alarms. The 7HI is also available with an optional 24 Vac/Vdc supply.
|
|
Supply Voltage: |
100-240 Vac (+10%, -15%), 50/60
Hz |
|
|
or 24 Vac/Vdc (±10%) |
|
Operating Ambient: |
0-50°C, 20-85% RH
non-condensing |
|
Inputs: |
T/C Types J, K, L, R, S, T and N (°C,
°F); |
|
|
Pt 100 3W RTD (°C, °F);
mAdc, mVdc, Vdc |
|
Mounting: |
Panel Mount |
|
Output Ratings: |
|
|
Output
1: |
|
Relay, 3A/250 Vac, 3A/30 Vdc, SPDT,
Resistive |
|
|
Alarm 1, Direct or Reverse
Acting |
|
Output
1: |
|
Relay, 3A/250 Vac, 3A/30 Vdc, SPDT,
Resistive |
|
|
Alarm 2, Direct or Reverse
Acting |
|
Output
3: |
|
Relay, 2A/250 Vac, 2A/ 30 Vdc, SPST, NO,
Resistive |
|
|
(7HI) |
|
Optional Alarm 3, Direct or
Reverse Acting |
|
Output
3: |
|
Isolated 0 to 20 mA or 4 to 20 mA, (500W
max.) |
|
|
(7HK) |
|
Isolated 0 to 10 Vdc (by solder
jumper - recalibration required), |
|
|
(5kW min.) Optional
Retransmission of PV |
| Thermocouple and RTD Input Range Table |
| Input Type |
°C Range |
°F Range |
| TC J |
-100 to 1000 |
-150 to 1850 |
| TC K |
-100 to
1370 |
-150 to
2500 |
| TC L |
-100 to 900 |
-150 to 1650 |
| TC R |
0 to 1760 |
0 to 3200 |
| TC S |
0 to 1760 |
0 to 3200 |
| TC T |
-100 to 400 |
-150 to 750 |
| TC N |
0 to 1400 |
0 to 2550 |
| RTD Pt100 |
-200 to 600 |
-320 to
1100 |
| RTD Pt100 |
-199.9 to 600.0 |
|
|
|
Alarm Standby Function The
7HI/7HK have an Alarm Standby function to allow masking of the process low
alarm condition if the process variable has not traversed the low alarm
threshold for the first time. |
|
Measurement Offset A
programmable sensor offset is provided for instances when it is not possible to
locate the sensor in the ideal location. This offset can be applied to all
inputs and is programmable for °C or °F. |
| |  | |